Capabilities of TileFlow
|
|
|
|
TileFlow can be used to model both raised-floor and non-raised floor data centers. Its important features are:
|
|
 TileFlow workspace
|
|
An Intuitive Graphical User Interface
TileFlow
includes an easy-to-use graphical user interface. Its important features are:
- Point-and click, mouse-driven
- Simultaneous two- and three-dimensional views of floor
- Zoom, pan, rotate, turn, and tilt tools
- Extensive database of air-conditioning units (CRAC units), perforated tiles, and server racks from leading manufacturers
- Use-definable characteristics of CRAC units, perforated tiles, and server racks
- Under-floor obstructions and partitions to represent pipes, cables, and other obstructions in the plenum
- Above-floor rooms with different airflow connections
- Above-floor partitions and blockages
- Supplemental cooling units (XDO, XDV, and in-row coolers)
- Inlet/outlet vents on perimeter walls, ceiling, and solid blocks
- Return ceiling plenum
- Dynamic count of objects on the floor
- Inspect Tool to view characteristics of individual air-conditioning units, perforated tiles, and server racks
|
|
|
|
|
|
|
|
 Under-floor blockages representing pipes and cables
|
|
Top of page
Efficient and Accurate Solution Technique
TileFlow uses efficient and accurate solution technique for calculating the three-dimensional flow fields (under and above the the raised floor) and temperature distribution in raised-floor data centers.
- The technique of Computational Fluid Dynamics (CFD) is used for solving the equations governing the fluid flow and heat transfer in
the data center.
- Use of advanced solution techniques allows calculation of airflow and temperature distribution in practical data centers within a
short time on a PC.
- The calculated flow rates and rack inlet temperatures agree well (usually within 10%) with measured values.
The accuracy of the calculated results, the short turnaround times, and the ease-of-use make TileFlow an ideal tool for simulating
cooling performance of data centers.
Top of page
Comprehensive Visualization of Results
TileFlow
provides a variety of formats for presenting the calculated results. The results are easy to understand. They provide a clear understanding of the cooling performance of the data center, help in identifying the regions with insufficient cooling and explaining the cause(s) of insufficient cooling, and give guidance for improving the cooling performance.
- Color maps of airflow rates through the perforated tiles and associated cooling capacities
- Contour plot of pressure under the raised floor, overlaid with velocity vectors
- Display of cooling plumes through the perforated tiles. This display can be in the form of fireworks, fountains, or arrows
- Inspect tool to probe at a specific location
- Results at a Glance for a quick summary of results
- Detailed summary of results (as a text file)
- Airflow rates can be imported into Microsoft Excel
- Temperature fog, which depicts the three-dimensional temperature distribution in the data center
- Temperature distribution and airflow pattern on selected vertical and horizontal planes (billboards)
- Thermomemter to display local temperature
- Flashing lights to identify overheated racks
- Animation of air movement above the raised floor
- Detailed temperature data for racks (maximum inlet and exhaust temperatures and temperatures at various elevations near the front
and rear faces)
- Return-air temperatures for CRAC units
- Cooling provided by XDO units, XDV units, and in-row coolers
- Rack temperature maps
|
|
|
 Temperature distribution and flow pattern on a vertical plane
 Temperature distribution and flow pattern on a horizontal plane
|
|
|
|
 Velocity vectors and pressure distribution under the raised floor
|
|
|
|
|
 Display of cooling plumes through the perforated tiles
Top of page
|
|
|
|
|
|
|
|
|
|
|
|
|